Problem: This Elkhart commercial metal roof leaked around a furnace penetration and the box gutter between buildings. The metal remained serviceable, with no corrosion or previous coating.
Why coating: For this project, replacement was estimated at three to four times the coating cost. Restoring the existing metal also avoided opening the building envelope during a tear-off.
Work: Elite Roofing pressure-washed the roof, applied rust-preventive primer, reinforced all seams with tape embedded in base coat, and applied two acrylic topcoats.
Reported result: No leaks were reported during the first three years after coating. Elite Roofing also completed coating work on five additional buildings.